Effects of paired climbing fibre stimulation on EPSP and after-potentials
After-depolarization | After-hyperpolarization | |||
---|---|---|---|---|
|
|
|||
Amplitudea (mV) | Duration (ms) | Amplitudeb (mV) | Durationc (ms) | |
1st response | 7.0 ± 2.4 (10) | 110.5 ± 27.9 (10) | 3.7 ± 0.7 (10) | 149.1 ± 32.6 (9) |
2nd response | ||||
ISI, 400 ms | 5.6 ± 2.6* (10) | 128.1 ± 63.9 (10) | 2.9 ± 1.5* (10) | 129.1 ± 33.3 (9) |
ISI, 800 ms | 5.8 ± 2.9 (10) | 129.5 ± 52 (10) | 2.8 ± 1.1* (10) | 125.2 ± 32* (9) |
-
All data are expressed as means ±s.d. with the sample size given in parentheses.
-
↵* P < 0.05 compared with the value of the first response (Wilcoxon signed-rank test).
-
↵a Amplitudes of after-depolarization were measured 50 ms after the stimulus artefacts.
-
↵b Amplitudes of after-hyperpolarization were measured at the peak.
-
↵c Durations of after-hyperpolarization were measured as the times between the data points crossing the half-maximum amplitudes.